PZUxB series
Parametrics
| Type number | Package version | Package name | Size (mm) | VZ [nom] (V) | IZ (mA) | Tolerance +/- | VZ [max] (V) | IF [max] (mA) | VZ [min] (V) | Ptot (mW) | PZSM (W) | TJ [max] (°C) | Configuration |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PZU2.7B2 | SOD323F | SC-90 | 1.7 x 1.25 x 0.7 | 2.775 | 5 | 2% | 2.9 | 200 | 2.65 | 550 | 40 | 150 | single |
| PZU3.0B | SOD323F | SC-90 | 1.7 x 1.25 x 0.7 | 3 | 5 | 5% | 3.2 | 200 | 2.8 | 550 | 40 | 150 | single |
Package
| Type number | Orderable part number, (Ordering code (12NC)) | Status | Marking | Package | Package information | Reflow-/Wave soldering | Packing |
|---|---|---|---|---|---|---|---|
| PZU2.7B2 | PZU2.7B2,115 (934059811115) |
Active | H1 |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU3.0B | PZU3.0B,115 (934059743115) |
Active | G5 |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
All type numbers in the table below are discontinued.
| Type number | Orderable part number, (Ordering code (12NC)) | Status | Marking | Package | Package information | Reflow-/Wave soldering | Packing |
|---|---|---|---|---|---|---|---|
| PZU10B1 | PZU10B1,115 (934059799115) |
Obsolete | FH |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU10B3 | PZU10B3,115 (934059848115) |
Withdrawn / End-of-life | KB |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU11B1 | PZU11B1,115 (934059801115) |
Obsolete | FJ |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU11B3 | PZU11B3,115 (934059849115) |
Discontinued / End-of-life | KC |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU12B1 | PZU12B1,115 (934059802115) |
Withdrawn / End-of-life | FK |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU12B3 | PZU12B3,115 (934059851115) |
Discontinued / End-of-life | KD |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU13B1 | PZU13B1,115 (934059803115) |
Discontinued / End-of-life | FL |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU13B3 | PZU13B3,115 (934059852115) |
Obsolete | KE |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU15B1 | PZU15B1,115 (934059804115) |
Discontinued / End-of-life | FM |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU15B3 | PZU15B3,115 (934059853115) |
Discontinued / End-of-life | KF |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU16B1 | PZU16B1,115 (934059805115) |
Obsolete | FN |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU16B3 | PZU16B3,115 (934059854115) |
Withdrawn / End-of-life | KG |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU18B1 | PZU18B1,115 (934059806115) |
Withdrawn / End-of-life | FP |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU18B3 | PZU18B3,115 (934059855115) |
Obsolete | KH |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU2.7B1 | PZU2.7B1,115 (934059783115) |
Discontinued / End-of-life | F3 |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU20B1 | PZU20B1,115 (934059807115) |
Withdrawn / End-of-life | FQ |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU20B3 | PZU20B3,115 (934059856115) |
Withdrawn / End-of-life | KJ |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU22B1 | PZU22B1,115 (934059808115) |
Withdrawn / End-of-life | FR |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU22B3 | PZU22B3,115 (934059857115) |
Discontinued / End-of-life | KK |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU24B1 | PZU24B1,115 (934059809115) |
Discontinued / End-of-life | FS |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU24B3 | PZU24B3,115 (934059858115) |
Obsolete | KL |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU3.0B1 | PZU3.0B1,115 (934059784115) |
Discontinued / End-of-life | F4 |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU3.3B1 | PZU3.3B1,115 (934059785115) |
Discontinued / End-of-life | F5 |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU3.6B1 | PZU3.6B1,115 (934059786115) |
Discontinued / End-of-life | F6 |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU3.9B1 | PZU3.9B1,115 (934059787115) |
Discontinued / End-of-life | F7 |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU4.3B1 | PZU4.3B1,115 (934059788115) |
Obsolete | F8 |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU4.3B3 | PZU4.3B3,115 (934059838115) |
Discontinued / End-of-life | HS |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU4.7B1 | PZU4.7B1,115 (934059789115) |
Discontinued / End-of-life | F9 |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU4.7B3 | PZU4.7B3,115 (934059839115) |
Discontinued / End-of-life | HT |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU5.1B1 | PZU5.1B1,115 (934059791115) |
Discontinued / End-of-life | FA |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU5.1B3 | PZU5.1B3,115 (934059841115) |
Discontinued / End-of-life | HU |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU5.6B1 | PZU5.6B1,115 (934059793115) |
Withdrawn / End-of-life | FB |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU5.6B3 | PZU5.6B3,115 (934059842115) |
Discontinued / End-of-life | HV |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU6.2B1 | PZU6.2B1,115 (934059794115) |
Discontinued / End-of-life | FC |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU6.2B3 | PZU6.2B3,115 (934059843115) |
Discontinued / End-of-life | HW |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU6.8B1 | PZU6.8B1,115 (934059795115) |
Discontinued / End-of-life | FD |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU6.8B3 | PZU6.8B3,115 (934059844115) |
Discontinued / End-of-life | HX |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU7.5B1 | PZU7.5B1,115 (934059796115) |
Discontinued / End-of-life | FE |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU7.5B3 | PZU7.5B3,115 (934059845115) |
Discontinued / End-of-life | HY |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU8.2B1 | PZU8.2B1,115 (934059797115) |
Discontinued / End-of-life | FF |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU8.2B3 | PZU8.2B3,115 (934059846115) |
Discontinued / End-of-life | HZ |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU9.1B1 | PZU9.1B1,115 (934059798115) |
Discontinued / End-of-life | FG |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
| PZU9.1B3 | PZU9.1B3,115 (934059847115) |
Discontinued / End-of-life | KA |
SC-90 (SOD323F) |
SOD323F |
WAVE_BG-BD-1
|
SOD323F_115 |
Environmental information
| Type number | Orderable part number | Chemical content | RoHS | RHF-indicator |
|---|---|---|---|---|
| PZU2.7B2 | PZU2.7B2,115 | PZU2.7B2 |
|
|
| PZU3.0B | PZU3.0B,115 | PZU3.0B |
|
|
All type numbers in the table below are discontinued.
| Type number | Orderable part number | Chemical content | RoHS | RHF-indicator |
|---|---|---|---|---|
| PZU10B1 | PZU10B1,115 | PZU10B1 |
|
|
| PZU10B3 | PZU10B3,115 | PZU10B3 |
|
|
| PZU11B1 | PZU11B1,115 | PZU11B1 |
|
|
| PZU11B3 | PZU11B3,115 | PZU11B3 |
|
|
| PZU12B1 | PZU12B1,115 | PZU12B1 |
|
|
| PZU12B3 | PZU12B3,115 | PZU12B3 |
|
|
| PZU13B1 | PZU13B1,115 | PZU13B1 |
|
|
| PZU13B3 | PZU13B3,115 | PZU13B3 |
|
|
| PZU15B1 | PZU15B1,115 | PZU15B1 |
|
|
| PZU15B3 | PZU15B3,115 | PZU15B3 |
|
|
| PZU16B1 | PZU16B1,115 | PZU16B1 |
|
|
| PZU16B3 | PZU16B3,115 | PZU16B3 |
|
|
| PZU18B1 | PZU18B1,115 | PZU18B1 |
|
|
| PZU18B3 | PZU18B3,115 | PZU18B3 |
|
|
| PZU2.7B1 | PZU2.7B1,115 | PZU2.7B1 |
|
|
| PZU20B1 | PZU20B1,115 | PZU20B1 |
|
|
| PZU20B3 | PZU20B3,115 | PZU20B3 |
|
|
| PZU22B1 | PZU22B1,115 | PZU22B1 |
|
|
| PZU22B3 | PZU22B3,115 | PZU22B3 |
|
|
| PZU24B1 | PZU24B1,115 | PZU24B1 |
|
|
| PZU24B3 | PZU24B3,115 | PZU24B3 |
|
|
| PZU3.0B1 | PZU3.0B1,115 | PZU3.0B1 |
|
|
| PZU3.3B1 | PZU3.3B1,115 | PZU3.3B1 |
|
|
| PZU3.6B1 | PZU3.6B1,115 | PZU3.6B1 |
|
|
| PZU3.9B1 | PZU3.9B1,115 | PZU3.9B1 |
|
|
| PZU4.3B1 | PZU4.3B1,115 | PZU4.3B1 |
|
|
| PZU4.3B3 | PZU4.3B3,115 | PZU4.3B3 |
|
|
| PZU4.7B1 | PZU4.7B1,115 | PZU4.7B1 |
|
|
| PZU4.7B3 | PZU4.7B3,115 | PZU4.7B3 |
|
|
| PZU5.1B1 | PZU5.1B1,115 | PZU5.1B1 |
|
|
| PZU5.1B3 | PZU5.1B3,115 | PZU5.1B3 |
|
|
| PZU5.6B1 | PZU5.6B1,115 | PZU5.6B1 |
|
|
| PZU5.6B3 | PZU5.6B3,115 | PZU5.6B3 |
|
|
| PZU6.2B1 | PZU6.2B1,115 | PZU6.2B1 |
|
|
| PZU6.2B3 | PZU6.2B3,115 | PZU6.2B3 |
|
|
| PZU6.8B1 | PZU6.8B1,115 | PZU6.8B1 |
|
|
| PZU6.8B3 | PZU6.8B3,115 | PZU6.8B3 |
|
|
| PZU7.5B1 | PZU7.5B1,115 | PZU7.5B1 |
|
|
| PZU7.5B3 | PZU7.5B3,115 | PZU7.5B3 |
|
|
| PZU8.2B1 | PZU8.2B1,115 | PZU8.2B1 |
|
|
| PZU8.2B3 | PZU8.2B3,115 | PZU8.2B3 |
|
|
| PZU9.1B1 | PZU9.1B1,115 | PZU9.1B1 |
|
|
| PZU9.1B3 | PZU9.1B3,115 | PZU9.1B3 |
|
|
Documentation (8)
| File name | Title | Type | Date |
|---|---|---|---|
| AN90063 | Questions about package outline drawings | Application note | 2025-10-22 |
| sym068 | Graphic symbol: d.o. | Block diagram | 2009-11-04 |
| SOD323F | 3D model for products with SOD323F package | Design support | 2025-09-20 |
| SOT323F | 3D model for products with SOT323F package | Design support | 2019-01-22 |
| Nexperia_package_poster | Nexperia package poster | Leaflet | 2020-05-15 |
| SC-90_SOD323F_mk | plastic, surface-mounted package; 2 leads; 1.7 mm x 1.25 mm x 0.7 mm body | Marcom graphics | 2017-01-28 |
| SOD323F | plastic, surface-mounted package; 2 leads; 1.7 mm x 1.25 mm x 0.7 mm body | Package information | 2022-05-27 |
| WAVE_BG-BD-1 | Wave soldering profile | Wave soldering | 2021-09-08 |
Support
If you are in need of design/technical support, let us know and fill in the answer form we'll get back to you shortly.
Ordering, pricing & availability
- PZU10B1
- PZU10B3
- PZU11B1
- PZU11B3
- PZU12B1
- PZU12B3
- PZU13B1
- PZU13B3
- PZU15B1
- PZU15B3
- PZU16B1
- PZU16B3
- PZU18B1
- PZU18B3
- PZU2.7B1
- PZU2.7B2
- PZU20B1
- PZU20B3
- PZU22B1
- PZU22B3
- PZU24B1
- PZU24B3
- PZU3.0B
- PZU3.0B1
- PZU3.3B1
- PZU3.6B1
- PZU3.9B1
- PZU4.3B1
- PZU4.3B3
- PZU4.7B1
- PZU4.7B3
- PZU5.1B1
- PZU5.1B3
- PZU5.6B1
- PZU5.6B3
- PZU6.2B1
- PZU6.2B3
- PZU6.8B1
- PZU6.8B3
- PZU7.5B1
- PZU7.5B3
- PZU8.2B1
- PZU8.2B3
- PZU9.1B1
- PZU9.1B3
Sample
As a Nexperia customer you can order samples via our sales organization.
If you do not have a direct account with Nexperia our network of global and regional distributors is available and equipped to support you with Nexperia samples. Check out the list of official distributors.